The Thermo Scientific Corona Veo RS Charged Aerosol Detector (CAD), typically paired with the Peak Scientific Corona Nitrogen 1010 (Peak 1010) gas generator, forms a complete HPLC/UHPLC universal detection solution for non-volatile and semi-volatile compounds lacking UV chromophores. The Corona Veo RS employs charged aerosol detection technology in which column eluent is nebulized with high-purity nitrogen, the solvent is evaporated in a heated drift tube (adjustable 5–100°C), and the remaining non-volatile analyte particles acquire a charge via corona discharge before being quantified by an electrometer. Unlike RI or ELSD, CAD provides a near-uniform response essentially independent of molecular structure, allowing reliable quantification of sugars, carbohydrates, polymers, surfactants, phospholipids, and pharmaceutical excipients or impurities—even without authenticated reference standards—within a single injection across a wide dynamic range. The RS variant is engineered for rapid separation workflows, featuring a maximum data acquisition rate of 200 Hz to fully capture narrow UHPLC peaks, a FocusJet concentric nebulizer for improved semi-volatile sensitivity, electronic gas-flow control, and an integrated TTL-controlled six-port switching valve to divert early-eluting matrix to waste. It operates over a mobile-phase flow range of 0.01–2.0 mL/min, connects via USB 2.0 to Thermo Scientific Chromeleon CDS, and requires a clean nitrogen or dry-air supply at 70–80 psig (≈4.8–5.5 bar) with a typical consumption of ~4 L/min. The companion Peak 1010 nitrogen generator is purpose-built for CAD detectors, utilizing membrane separation technology to deliver up to 5 L/min of >98% pure dry nitrogen at 80 psi (5.5 bar)—precisely matching the CAD's gas demand—and is available either as a benchtop module for connection to an existing compressed-air line or with an integrated scroll compressor (Corona 1010A) for standalone operation. Its compact footprint (156 × 417 × 540 mm) allows direct stacking beneath the Corona Veo RS to conserve laboratory bench space. The generator reaches operating setpoint within approximately five minutes of startup, includes front-panel pressure indication and fault diagnostics, and eliminates the inconvenience, safety concerns, and purity variability associated with high-pressure nitrogen cylinders. Together, the Corona Veo RS CAD and Peak 1010 nitrogen generator provide pharmaceutical QC/QA, contract research, food/beverage, and polymer-analysis laboratories with a sensitive, reproducible, and low-maintenance universal LC detection platform especially suited for impurity profiling, forced-degradation studies, formulation characterization, and cleaning-validation sample analysis.
Technical Specifications
|
Item |
Thermo Scientific Corona™ Veo™ RS CAD |
Peak Scientific Corona Nitrogen 1010 |
|---|---|---|
|
Catalog / Model No. |
5081.0020 |
Corona 1010 (w/o compressor) / 1010A (w/ compressor) |
|
Detection / Gas Type |
Charged Aerosol Detection (CAD) |
Nitrogen (N₂), membrane technology |
|
Mobile Phase Flow Rate |
0.01 – 2.0 mL/min |
— |
|
Data Acquisition Rate |
Up to 200 Hz |
— |
|
Evaporation Temperature |
Ambient +5°C to 100°C (continuously adjustable) |
— |
|
Analog Output Range |
1 pA to 500 pA (1-2-5 sequence) |
— |
|
Inlet Gas Requirement |
N₂ or dry air, 70–80 psig (482–551 kPa), ~4 L/min |
Clean compressed air inlet 110–130 psi (for 1010) |
|
N₂ Output Flow (Max) |
— |
5 L/min |
|
N₂ Output Pressure |
— |
80 psi / 5.5 bar |
|
N₂ Purity |
— |
>98% (typical) |
|
Interface / Control |
USB 2.0 to Chromeleon CDS; integrated stream-switch valve |
On/off & status LEDs; optional touchscreen (1010A) |
|
Warm-up Time |
<30 min to 35°C evaporation temp |
~5 min |
|
Power Requirement |
100/240 V AC, 50/60 Hz, 100 VA |
100–230 V AC, 50/60 Hz (1010: ~23 VA; 1010A: ≤680 VA) |
|
Dimensions (H×W×D) |
22.9 × 44.5 × 55.9 cm (9 × 17.5 × 22 in) |
15.6 × 41.7 × 54.0 cm (6.1 × 16.4 × 21.3 in) |
|
Weight |
14.3 kg (31.5 lb) |
1010: ~12 kg; 1010A: ~31.5 kg |
|
Certifications |
UL/IEC 61010-1, FCC Part 15 / ICES-003 Class A |
CE, CSA, FCC |